John,
We are going to use the same project number: 2006-13.
The curb return needs to be at least 10’ from the inlet. This is a low point inlet (in fact it is the only inlet on this stretch of Sojourn) and we need to maintain the 10’ variable
height curb on each side of the inlet. Beyond that length you are welcome to tie in at any point.
Please let me know if you have any additional questions.
Thanks,
Clay Barnett, P.E.
Town Engineer
Town of Addison
16801 Westgrove Drive
Addison, TX 75001-2818
Office: (972) 450-2857
From: John Casey [mailto:tjcasey@glennengineering.com]
Sent: Thursday, June 02, 2011 4:10 PM
To: Clay Barnett
Cc: crobinson@gra-ce.net
Subject: RE: TCA Parking Lot Review
Clay,
A couple of questions:
1. Do you have the rest of the PW #?
2. How big of a deal is the 20’ radius? I didn’t do the initial layout on this, but it looks like we are about 10’ away from the edge of the curb inlet, and we only need 5’ to
get to 20’. Is that acceptable? At that point I’d need to redesign the curb ramp to angle it away from the inlet. Let me know if that’s how you would prefer to proceed.
The other questions I think I can answer/respond to, but was wondering if you had any clarification, especially on #2. Thanks.
T. John Casey, P.E.
Glenn Engineering Corporation
105 Decker Court, Suite 910
Irving, Texas 75062-2227
Office (972) 717- 5151
Cell (214) 734-7878
tjcasey@glennengineering.com
From: Clay Barnett [mailto:cbarnett@addisontx.gov]
Sent: Wednesday, June 01, 2011 3:25 PM
To: John Casey (tjcasey@glennengineering.com)
Subject: FW: TCA Parking Lot Review
John,
Attached are the preliminary comments. We are still working on a final version. We do want to insure that the fire lane meets the ordinances or there is satisfactory documentation
as to why they would not. Additionally, we want to insure that no more than 4 cfs is discharged to Sojourn.
If you have any questions, please let me know.
Thanks,
Clay Barnett, P.E.
Town Engineer
Town of Addison
16801 Westgrove Drive
Addison, TX 75001-2818
Office: (972) 450-2857
From: Chris Robinson [mailto:crobinson@gra-ce.net]
Sent: Wednesday, May 25, 2011 5:29 PM
To: Clay Barnett
Subject: TCA Parking Lot Review
Clay,
The plan review is attached. Please email me or Bruce if you have any questions. Bruce is familiar with the project if something urgent comes up.
Thank you,
Chris Robinson, P.E.
Grantham & Associates
6570 Naaman Forest Blvd.
Suite #200, LB 2
Garland, TX 75044
972-864-2333 ext. 121
972-342-5351 cell
972-864-2334 fax