Thanks for the feedback Clay, I'll discuss it with them. Have a good weekend! ________________________________ From: Clay Barnett [mailto:cbarnett@addisontx.gov] Sent: Friday, May 14, 2010 3:26 PM To: Herrera, Ignacio Subject: RE: Daseke Home / fire-water connection Ignacio, That can be done, but you may want to discuss this with your client. Water bills include a monthly fee based on meter size as well as usage. Usually 6” meters are used in midrise office buildings. I can’t say as I have ever seen one used for a residence. Thanks, Clay Barnett, P.E. Town Engineer Town of Addison 16801 Westgrove Drive Addison, TX 75001-2818 Office: (972) 450-2857 From: Herrera, Ignacio [mailto:IHerrera@Halff.com] Sent: Friday, May 14, 2010 3:21 PM To: Clay Barnett Subject: RE: Daseke Home / fire-water connection The idea was to combine water and fire into one service line. Do they need to be separated? ________________________________ From: Clay Barnett [mailto:cbarnett@addisontx.gov] Sent: Friday, May 14, 2010 3:17 PM To: Herrera, Ignacio Subject: RE: Daseke Home / fire-water connection Ignacio, I am somewhat confused. Is it a domestic service or a fire service? Either way it must be metered. If it is a fire service it must have a double check detector assembly in lieu of a double check valve assembly. If it is a domestic service, it is unlikely that anything larger than a 2” meter is required. If you have any additional questions, please let me know. Thanks, Clay Barnett, P.E. Town Engineer Town of Addison 16801 Westgrove Drive Addison, TX 75001-2818 Office: (972) 450-2857 From: Herrera, Ignacio [mailto:IHerrera@Halff.com] Sent: Friday, May 14, 2010 2:32 PM To: Clay Barnett Subject: Daseke Home / fire-water connection Hi Clay, I'm in the process of completing the utility plan for the Daseke home. Fire system is yet to be designed, but for starts I am going with a 6" service line (which is fairly large, but I hesitate to go any smaller until a fire engineer determines what it needs to be). At this point, however, I would like to ask you if there is any particular requirement with installation of domestic water service in combination with fire. Currently I call for 1. domestic service, 2. Reducer (meter), 3. double check valve, and backflow prevention device. Is there anything else that I would need to add? Thanks in advance, Ignacio Ignacio N. Herrera, P.E. Civil Engineer HALFF ASSOCIATES, INC. 1201 North Bowser Road Richardson, Texas 75081 Phone 214-217-6646 Fax 214-739-0095 www.halff.com ****************************************************************************************************************** This e-mail and any files or attachments transmitted with it contains Information that is confidential and privileged. This document may contain Protected Health Information (PHI) or other information that is intended only for the use of the individual(s) and entity(ies) to whom it is addressed. If you are the intended recipient, further disclosures are prohibited without proper authorization. If you are not the intended recipient, any disclosure, copying, printing, or use of this information is strictly prohibited and possibly a violation of federal or state law and regulations. If you have received this information in error, please delete it and notify Hamid Khaleghipour at 972-450-2868 immediately. Thank you. ******************************************************************************************************************* ****************************************************************************************************************** This e-mail and any files or attachments transmitted with it contains Information that is confidential and privileged. This document may contain Protected Health Information (PHI) or other information that is intended only for the use of the individual(s) and entity(ies) to whom it is addressed. If you are the intended recipient, further disclosures are prohibited without proper authorization. If you are not the intended recipient, any disclosure, copying, printing, or use of this information is strictly prohibited and possibly a violation of federal or state law and regulations. If you have received this information in error, please delete it and notify Hamid Khaleghipour at 972-450-2868 immediately. Thank you. *******************************************************************************************************************