Chris, Could you have a look at this and make sure it meets the TCEQ 290 requirements? Also, we need an invoice for the street light surveys. Thanks, Clay Barnett, P.E. Town Engineer Town of Addison 16801 Westgrove Drive Addison, TX 75001-2818 Office: (972) 450-2857 P Please consider the environment before printing this email. -----Original Message----- From: Glen Kistenmacher [mailto:glen@kistenmacher.com] Sent: Monday, September 21, 2009 3:21 PM To: Clay Barnett Cc: 'Jim Kinder' Subject: FW: Water Main - Sewer Service Crossing, Best Press Expansion Clay, Upon further review, we apparently do not have the length necessary to develop the required casing length for the crossing. The only remaining alternate that I see will be in the TCEQ Regulations - Section 290.44.e.4.B.iv.III (contained on Page 52 of the attachment to this email). This requires either the casing of the waterline, or the construction of the waterline with ductile iron or steel pipe. This change in pipeline material would exist from the new water / fire main along the west side of the property to the new fire hydrant. Joints would need to be welded, and the water and wastewater mains would need to be pressure tested in accordance with the remainder of this section. Can you please review and give us your thought prior to us proceeding? Thanks. -- Glen G. Glen Kistenmacher, P. E. Kistenmacher Engineering Co., Inc. Civil Engineering - Land Planning - Surveying Dallas Office 6336 Greenville Avenue, Suite C Dallas, Texas 75206 214-234-0011 214-234-0012 (fax) El Paso Office 1420 Geronimo Drive, Suite A-2 El Paso, Texas 79925 915-778-4476 915-778-4504 (fax) _____ From: Glen Kistenmacher [mailto:glen@kistenmacher.com] Sent: Wednesday, September 16, 2009 3:48 PM To: 'Clay Barnett' Cc: 'Jim Kinder' Subject: Water Main - Sewer Service Crossing, Best Press Expansion Clay, Jim Kinder indicated that you would like to see a detail of the proposed water main - sewer service crossing for the Best Press project. Attached is that detail, for review and comment, based on the TCEQ rules and regulations. As you probably already know, this condition is occurring near the SE corner of the existing building. After reviewing, please let us know if you have any questions or need any additional information / clarification. Thanks. G. Glen Kistenmacher, P. E. Kistenmacher Engineering Co., Inc. Civil Engineering - Land Planning - Surveying Dallas Office 6336 Greenville Avenue, Suite C Dallas, Texas 75206 214-234-0011 214-234-0012 (fax) El Paso Office 1420 Geronimo Drive, Suite A-2 El Paso, Texas 79925 915-778-4476 915-778-4504 (fax)