New RFI No. 20 As of 10-Jul-2009 12:19 PM CT Vitruvian Infrastructure Phase 1B 4010 Marsh Lane Addison, Texas 75001 Project Number: 1308B Status: Outstanding Subject Plan grade bust on storm line SD-A1 Reason Code None Question On revised sheet 33 for line SD-A1, the profiles show a proposed 2.00% slope between stations 2+94.35 and 3+31.05. When proposed flowlines are calculated, this slope is actually around 1.66% (at 36.7 LF). Proposed Solution Joel, per our conversation, NTC is to correct this bust by running at a 2.00% from 2+94.35 to 3+31.05, and modify the 5'x5' RCB flowline elevation up at station 3+31.05. NTC will note the flowline elevation change at station 3+31.05 on our as-built drawings and documents. Attached Files (none) Section: 2 - Sitework Int. Tracking #: Days Elapsed: 0 From: Andrew Rolph Originated: 10-Jul-2009 12:19 PM CT To: Jennifer Haynes, PE (First Recipient) Requested By: 13-Jul-2009 12:08 PM CT Copy to: Andrew Rolph Andy Nord Joel Massey Nick Jacob Jennifer Haynes, PE Zach Fusilier Bruce Dunne Craig Benckendorf Clay Barnett Additional Info Proposed Solution Impact Critical Path? No Cost Change: None Time Change: None Discipline Code: Civil Drawing Numbers: 33 Needs Drawing Change? Yes History (Chronological Order) No history to display. Final Response (Closing) This item is still open. No final response to display. .................................................................................. Copyright (c) 1999-2009, Systemates, Inc. View the User Agreement for legal restrictions and terms of use applicable to this site. Use of this site signifies your agreement to the terms of use specified in the User Agreement. Projectmates - Blueprint for e-Management