>> Leave comment << Response to RFI No. 39 As of 29-Sep-2010 10:43 AM CT Vitruvian Infrastructure Phase 1C Park 4010 Marsh Lane Addison, Texas 75001 Project Number: 1308C Status: Complete Subject Sanitary Sewer Cleanouts Reason Code None Question Just south of the park parking lot, there are existing sanitary sewer cleanouts that in conflict with the construction of the screenwall. From what I understand, there is a sanitary sewer that needs to be abandoned as well. Please provide direction. Proposed Solution Attached Files (none) Section: 2 - Sitework Int. Tracking #: Days Elapsed: 6 From: Jennifer Haynes Originated: 23-Sep-2010 11:53 AM CT To: Nick Jacob (First Recipient) Requested By: 26-Sep-2010 12:00 AM CT (Original 26-Sep-2010 11:49 AM CT) Copy to: Joel Massey Eric Little Wade Geistweidt Clay Barnett Additional Info Proposed Solution Impact Critical Path? Yes Cost Change: Yes, may be Time Change: None Discipline Code: Civil Drawing Numbers: Needs Drawing Change? Yes History (Chronological Order) Type Routed Billable n/a Memo please advise Attached Files (none) From: Nick Jacob Sent: 23-Sep-2010 11:57 AM CT To: Joel Massey Requested By: 26-Sep-2010 11:49 AM CT Copy to: Bruce Dunne Type Routed Billable n/a Memo The town would like to see the sewer line abandoned to the east of the access device that was installed with Phase 1B. The solution would be to dig down and cap the line going to the east from the access device. The two cleanouts to the east could then be cut & plugged below grade. Please revise the plans for this and include in the change order. A solution needs to be proposed for the cleanout to the west. Attached Files (none) From: Clay Barnett Sent: 27-Sep-2010 10:47 AM CT To: Bruce Dunne Requested By: 26-Sep-2010 11:49 AM CT Copy to: Joel Massey Eric Little Nick Jacob Jennifer Haynes Wade Geistweidt Final Response (Closing) Response Per ICON: The existing sewer line to the east of the recently installed access device will be abandoned. The contractor will need to dig down on the east side of the access device and cap the line going to the east. The two cleanouts to the east of the access devise will then be cut & plugged below grade. The cleanout to the west of the access devise will need to be cut and plugged at the wye connection to the existing main. The double cleanout can then be removed. Drawings will be revised to show these revisions and a change order issued to account for the work. Billable n/a Attached Files (none) From: Eric Little Sent: 29-Sep-2010 10:43 AM CT To: Jennifer Haynes Copy to: Nick Jacob Bruce Dunne Clay Barnett .................................................................................. Copyright (c) 1999-2010, Systemates, Inc. View the User Agreement for legal restrictions and terms of use applicable to this site. Use of this site signifies your agreement to the terms of use specified in the User Agreement. Projectmates - The Capital Project Management Software